Basic Specification and Main Parameters
Model Name
|
JXL11-63
|
Pole number
|
2P,4P
|
Standard
|
IEC61008.1,EN61008.1
|
Rated working current(In)
|
16A,25A,40A,50A,63A
|
Rated working voltage(Ue)
|
240V(2P),415V(4P)
|
Rated frenquency
|
50/60Hz
|
Rated insulation voltage(Ui)
|
500V
|
Rated residual operating current(I∆n)
|
30mA,100mA,300mA,500mA
|
Rated residual un-operating current(I∆no)
|
15mA,50mA,150mA,250mA
|
Sensibility
|
A&AC Type
|
Rated making and breaking capacity(I∆m)
|
In≤40A--500A In=63A--630A
|
Rated limiting short-circuit current(Inc)
|
6000A
|
Rated limited residual short-circuit current I∆c(A)
|
6000A
|
Mechanical life
|
2000
|
Electric life
|
2000
|
Protection degree
|
IP20
|
Enviroment temeperature
|
-5℃~+40℃
|
Installation level
|
≤2000m
|
Connecting Wire Size
Rated Current In(A)
|
Nominal cross-section of wire(mm)
|
≤10
|
1.5
|
10-20
|
2.5
|
20-25
|
4
|
25-32
|
6
|
32-50
|
10
|
50-63
|
16
|
Security Warning
● This product must be installed professionally.
● Operation with wet hands is strictly prohibited in case of electric shock hazard.
●The products don't have the dust-proof function with protection class IP20, please install in a sealed box when they are used in a dusty environment.
● Residual current protection features is tested and adjusted by the manufacturer,users can not adjust the product at random during usage.
● RCCB must not be wetted of soaked by rain, snow or water during transportation, storage and usage.
Outline & Installation Dimension
Installation
●Confirm the marks of the RCCB and the operating conditions is matched before Installation.
●Mounted on rail track, push up the retainer to make the RCCB fixed on the rail track.When need to remove the RCCB, just pull down the retainer.
●When the handle moving up and displaying symbol lON, the circuit is connected. When the handle moving down and displaying symbol I.OFF,the circuit is disconnected.
●Manual operation with the RCCB several times to confirm its flexible and reliable before power on.
●Test the button of the RCCB several times to confirm its flexible and reliable after power on.
Maintenance
●After running for a period of time, the RCCB should be inspected monthly,press the test button in power on state to confirm the
residual current protective properties is reliable or not.