Basic Specification and Main Parameters
Model Name
|
JXL1-125
|
Pole number
|
2P,4P
|
Standard
|
IEC61008.1,EN61008.1
|
Rated working current(In)
|
63A,80A,100A,125A
|
Rated working voltage(Ue)
|
240V(2P),415V(4P)
|
Rated frenquency
|
50/60Hz
|
Rated insulation voltage(Ui)
|
500V
|
Rated residual operating current(I∆n)
|
30mA,100mA,300mA,500mA
|
Rated residual un-operating current(I∆no)
|
15mA,50mA,150mA,250mA
|
Sensibility
|
A&AC Type
|
Rated making and breaking capacity(I∆m)
|
630A |
Rated limiting short-circuit current(Inc)
|
6000A
|
Rated limited residual short-circuit current I∆c(A)
|
6000A
|
Mechanical life
|
2000
|
Electric life
|
2000
|
Protection degree
|
IP20
|
Enviroment temeperature
|
-5℃~+40℃
|
Installation level
|
≤2000m
|
Connecting Wire Size
Rated Current In(A)
|
Nominal cross-section of wire(mm)
|
63
|
16
|
80
|
25
|
100
|
35
|
125
|
50
|
Security Warning
● This product must be installed professionally.
● Operation with wet hands is strictly prohibited in case of electric shock hazard.
●The products don't have the dust-proof function with protection class IP20, please install in a sealed box when they are used in a dusty environment.
● Residual current protection features is tested and adjusted by the manufacturer,users can not adjust the product at random during usage.
● RCCB must not be wetted of soaked by rain, snow or water during transportation, storage and usage.
Outline & Installation Dimension
Installation
●Confirm the marks of the RCCB and the operating conditions is matched before Installation.
●Mounted on rail track, push up the retainer to make the RCCB fixed on the rail track.When need to remove the RCCB, just pull down the retainer.
●When the handle moving up and displaying symbol lON, the circuit is connected. When the handle moving down and displaying symbol I.OFF,the circuit is disconnected.
●Manual operation with the RCCB several times to confirm its flexible and reliable before power on.
●Test the button of the RCCB several times to confirm its flexible and reliable after power on.
Maintenance
●After running for a period of time, the RCCB should be inspected monthly,press the test button in power on state to confirm the
residual current protective properties is reliable or not.
●RCCB must not be wetted of soaked by rain, snow or water during transportation, storage and usage.
Both MCB and MCCB are electrical line protection devices, but they also have some differences.The difference between a molded case circuit breaker and a miniature circuit breaker is that the electrica
[Circuit breaker knowledge] RCCB manufacturer will introduce the difference between the residual current circuit breaker and the residual current operated circuit breaker.