JXB1-63m C65

JXB1-63M Miniature Circuit Breaker

JXB1-63M is applicabletoalineofAC50/60Hz,230Vinsingle pole, 400V in double, three,

four poles for protecting overload andshortcircuit, and rated current up to 63A. It can also

be used for infrequent line conversionunderthe normal condition.The breaker is applicable

to lightingdistributionsysteminindustrialenterprise,commerciallydistrict, high-rise

building and dwelling house. It conforms with the standards of IEC 60898-1.

Get Quote
Basic Specification and Main Parameters

Model Name

JXB1-63M

Pole number

1P,2P,3P,4P

Standard

IEC60898/GB10963.1

Rated working current(In)

2A,4A,6A,10A,16A,20A,25A,32A,40A,63A

Rated working voltage(Ue)

230V(1P),400V(2P,3P,4P)

Rated frenquency

50Hz

Rated limiting short-circuit current(Inc)

3000A~6000A

Magnetic tripping curve

B(3-5In)  C(5-10In)  D(10-20In)

Mechanical life

10000

Electric life

4000

Protection degree

IP20

Enviroment temeperature

-5℃~+40℃

Fiducial temperature

30℃

Installation level

≤2000m

Biggest wiring ablity

25m㎡

Installation style

35mm din rail

Connection type

Tunnel style,Pin style,U style

The Over-current Protection Property

Ambient Temperature

Initial Status

Test Current

TestTime

Expected Result

Note

30±2℃

Cold position

1.13In

t≥1h

Non-release

_

Carried out immediately after previous test

1.45In

t<1h

Release

_

Cold position

 

2.55In

1s<t<60s

(In≤32A)

Release

Current smoothly rise to specified value within 5s

Cold position

2.55In

1s<t<120s

(In>32A)

Release

-5~+40℃

Cold position

3In

t≤0.1s

Non-release

Type B

5In

t<0.1s

Release

Type B

Cold position

5In

t≥0.1s

Non-release

Type C

Cold position

10In

t<0.1s

Release

Type C

Cold position

10In

t≥0.1s

Non-release

Type D

Cold position

20In

t<0.1s

Release

Type D

Applicable Conducting Wire

Rated Current(A)

 Nominal ross section of wire mm2

1-6A

1

10A

1.5

16A,20A

2.5

25A

4

32A

6

40A,50A

10

63A

16
Dimension

Related Products

News information

what is the difference between mcb and mccb

Both MCB and MCCB are electrical line protection devices, but they also have some differences.The difference between a molded case circuit breaker and a miniature circuit breaker is that the electrica

What is the difference between RCCB and leakage protector?

[Circuit breaker knowledge] RCCB manufacturer will introduce the difference between the residual current circuit breaker and the residual current operated circuit breaker.

Get in Touch

Captcha Code
×